Minolta EP1080 Manuel de service Page 47

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 90
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 46
EP1080 Series Condential
4-8
(3) Choose and access PC Calibration for
correction in service mode. Choose
“menu” to leave the service mode after
all.
Check pattern - Test signal: analog 800 x 600@60Hz
- Test pattern: In focus II or 64 gray RGBW
* After nishing ADC adjustment, check 64
gray RGBW pattern, adjust CW index in
color setting of service mode.
Inspection item - Color saturation
Criteria - There should not have any lack of RGBW.
The color should appear normal and sort in
right order.
- Color levels should be sufcient and normal.
(the unidentied color levels on both left and
right sides should not over 8 color levels.)
- Gray level should not have abnormal color
or heavy lines.
Defect specication table
Order Symptom Pattern Criteria
1 Bright pixel ( dots)
Black pattern
( IRE=O)
A+B=0
2 Dark pixel(dots) White pattern A+B=6
3 Unstable pixel (dots) Any pattern A+B=1
4 Adjacent dark pixel (dots) Any pattern A+B=0
5 Dark blemish (Dirty) Blue 60 pattern
A+B=2
(diameter <1/2 inch)
6 Bright blemish (Dirty) Gray 10 pattern
A+B=2
(diameter <1/2 inch)
7 Bright dot on frame Black pattern 2
In focus II / 64 gray
RGBW
Vue de la page 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 89 90

Commentaires sur ces manuels