Minolta EP1052 Spécifications Page 147

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 233
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 146
Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-28
Cleaning of the PC Drum Paper Separator Fingers
Cleaning of the Ds Positioning Collars
Cleaning of the Paper Dust Remover
Replacement of the Toner Antispill Mylar
10. Using a soft cloth dampened with alcohol, wipe clean the
Paper Separator Fingers.
11. Using a soft cloth dampened with alcohol, wipe clean the
Ds Positioning Collars.
12. Remove two screws, two compression coil springs and the
Synchronizing Roller Unit.
NOTE
When removing the Synchronizing Roller Unit, use care
not to lose the compression coil springs. At reinstallation,
fit the close-coiled end of the springs to the bosses on the
Imaging Unit.
13. Remove the Synchronizing Roller.
14. Using a brush, whisk the dust and dirt off the Filter.
15. Remove two screws and the Bias Seal.
(No Bias Seals are mounted in the copiers for the U.S.A.,
Canada, and Europe.)
16. Remove two screws and the Toner Antispill Mylar and re-
place the Mylar.
Vue de la page 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 232 233

Commentaires sur ces manuels