Code Description Detection Timing
C0650 Faulty Scanner Home
Position Sensor
The Scanner Home Position Sensor (PC6) does not
go from HIGH to LOW when the Scanner Motor (M5)
is energized for a given number of steps after the
sequence to bring the Scanner back to its home posi-
tion has been started at the end of a scan motion and
during re-shading.
The Scanner Home Position Sensor (PC6) does not
go from LOW to HIGH when the Scanner Motor (M5)
is energized for a given number of steps after a scan
motion has been started at the end of a Scanner
Home Position Sensor home check scan motion and
during re-shading.
C0B60 Bin Switching Motor
malfunction
If the Upper Home Position Sensor is LOW during an ini-
tial operation:
The Lower Home Position Sensor (PC33) is LOW
when the Bin Switching Motor (M1) starts turning for-
ward.
If the Lower Home Position Sensor (PC33) does not
go LOW at a time 2.5 sec. after the Bin Switching
Motor (M1) has started turning forward, the Bin
Switching Motor is kept deenergized for a given
period of time and then energized again to turn back-
ward. The Upper Home Position Sensor (PC32) does
not go LOW after the motor has started turning back-
ward.
The Upper Home Position Sensor (PC32) does not go
HIGH at a time 1 sec. after the Bin Switching Motor
(M1) has started turning forward.
When the Lower Home Position Sensor (PC33) goes
LOW, the Bin Switching Motor (M1) starts turning
backward. The Upper Home Position Sensor (PC32)
does not go LOW at a time 2.5 sec. after the motor
has started turning backward.
When the Lower Home Position Sensor (PC33) goes
LOW, the Bin Switching Motor (M1) starts turning
backward. The Lower Home Position Sensor (PC33)
does not go HIGH at a time 1 sec. after the motor has
started turning backward.
If the Lower Home Position Sensor is LOW during an ini-
tial operation:
The Upper Home Position Sensor (PC32) does not go
LOW at a time 2.5 sec. after the Bin Switching Motor
(M1) has started turning backward.
The Lower Home Position Sensor (PC33) does not go
HIGH at a time 1 sec. after the Bin Switching Motor
(M1) has started turning backward.