FrameMaker Ver5.5E(PC) Di152/Di183 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.07.26
S-27
5. ADJUST MODE
• Used at the factory for making adjustments.
5-1. Settings in the Adjust Mode
5-2. Adjust Mode Setting Procedure
<Procedure>
1. Set the machine into the Tech. Rep. Mode.
2. Press the following keys in this order:
Stop
→
Start.
3. Enter the code number corresponding to the subfunction to be used.
Code No.: 1 to 12 and 20
4. Press the Start key to display the current setting value.
5. Press the Clear key to clear the current setting value.
6. Enter the new setting value from the 10-Key Pad.
If any value outside the available setting range is entered, the Display shows “Err”
rejecting the entry. (The old setting value will reappear on the Display 1 sec. later.)
7. Press the Start key to validate the new setting value just entered.
<Exiting the Mode>
• Press the Panel Reset key until the initial screen reappears.
Code No. Description
--1 Printer CD Registration adjustment
--2 Printer FD Registration adjustment
--3 Scanner CD Zoom adjustment
--4 Scanner FD Zoom adjustment
--5 Scanner CD Registration adjustment
--6 Scanner FD Registration adjustment
--7 ADF FD Zoom adjustment
--8 ADF CD Registration adjustment
--9 ADF FD Registration adjustment
-10 ATDC Sensor Gain Manual adjustment
-11
-12 Test Print
-20
This test is for factory adjustment only and should
NOT be used.