Minolta Di183 Manuel de service Page 117

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 182
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 116
FrameMaker Ver5.5E(PC) Di152/Di183 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.07.26
S-29
Code No.
Setting (The default is ).
--7
<ADF FD Zoom adjustment>
Adjust the zoom ratio in the FD direction on the ADF side.
It is used when the machine is set up, the PH Unit or Scanner Drive
Cables have been replaced, or the Scanner has been removed.
--8
<ADF CD Registration adjustment>
Adjust registration in the CD direction on the ADF side.
It is used when the machine is set up, or the PH Unit or CCD Unit has
been replaced.
--9
<ADF FD Registration adjustment>
Adjust registration in the FD direction on the ADF side.
It is used when the PH Unit or Scanner Drive Cables have been
replaced, or the Scanner has been removed.
-10
<ATDC Sensor Gain Manual adjustment>
Adjust the ATDC Sensor voltage.
It is used when an IU of another machine is to be used or the T/C con-
trol voltage is to be changed.
The value, to which F-8 (ATDC Sensor Automatic Adjustment) has
been adjusted, is to be the setting value.
-11
Be sure to set to “1” whenever Memory Clear has been effected on
the 18-cpm machine.
-12
<Test Print>
This function is used to produce a test print, when a check is made
after a setting value of an Adjust function has been changed and on
image.
<Procedure>
1. Select the paper source (Bypass Tray cannot be selected).
2. Press the Start key to let the machine produce a test print.
-20
This test is for factory adjustment only and should NOT be used.
Highlighted
Setting
87.............................. ........................113
Description (%) 9.48............................100 .....................105.2
100
Setting
20.............................. ........................ 180
Description (mm) -8.0..............................0......................... +8.0
100
Setting
50.............................. ........................ 150
Description (mm) -5.................................0............................+5
100
Setting
123............................ ........................186
Description (V) 5.39...........................6.79.......................8.15
155
Setting 1
0
Vue de la page 116