FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T-43
• Determine if the failure is attributable to an input system (IR) or output system (engine).
Check Result Action
Copy made at a reduced
ratio.
Input system
Output system
Original
1177T03YA
Full-size copy Reduced copy
1177T04YA
Full-size copy Reduced copy
1177T05YA